Add: Room 2001、2002、2003、2011, Zhonghai International Plaza No. 237, Wannianquan Road, Qingdao, Shandong 266199 China
Tel: +86 532 8281 2277
Mobile : +86 186 5320 8877(WhatsApp)
Email: market@hiprove.cn lena@hiprove.cn

Part parameters
- Packaging Details:
- Delivery Time:
- Description:
Detailed introduction:
BB-200 Infant Incubator (Luxurious)
Function features
• Microprocessor based servo controlled temperature system
• Air temperature, skin temperature, timer and heat power separately displayed by LEO
• Humidity is adjustable continuously
• Skin temperature sensor fall protect function avoid over temperature
• Alarm functions: Power failure; Over temperature; Temperature deviation Temperature sensor failure; Fan failure
• Integral timer to record therapy time
•>37℃ temperature setting
•Silence/reset button for alarms
•A keypad lock prevent inadvertent changes the setting
Product main characteristic
• Trough for pulling and pushing ,which is convenient to add the water and wash
• Fan with low noise and long life-span
• Temperature deviation and over temperature could be amended in front panel directly
• A second thermal cut-out function for more safety
• The infant bed inclination angle is adjustable
• Six operating windows, two side access operating windows can be swiveled
• Cabinet with three drawers.silence castors
Transport and storage
Package
Each unit is packed in two wooden crate
※ Control unit and cabinet: 120*70*96CM ( N.W./G.W.: 80KG/110KG )
※ Hood: 97*56*63cm ( N.W./G.W.:15KG/40KG )
Transport and storage
Environment Temp: -10℃ ---- +70℃
Environment Relative Humidity: ≤80%
Atmospheric Pressure: 500~1060hPa

| Technical data | ||
| Power supply | AC110/220V 60/50Hz | |
| Power input | 420VA |
|
| Operating conditions |
Environment tmperature | 20℃~30℃ |
| Environment,relative humidity | 30%~75%RH |
|
| Environment air velocity of flow | <0.3m/s |
|
| Air Temperature control range |
25℃~38℃ |
|
| Skin temperature control range |
32℃~38.5℃ | |
| Skin temperature sensor accuracy |
±0.3℃ |
|
| Temperature fluctuation |
±0.5℃ |
|
| Uniformity of mattress temperature |
≤0.8℃ |
|
| Warm-up time |
≤45min |
|
| Internal noise level |
≤55dB(A) |
|
| Infant bed tilt angle |
±10° |
|
| Mattress size |
65cm(L)*37cm(W) |
|
| Trough capacity |
1200ml |
|
| Air filter | 0.5um | |
Standard configuration & Optional parts
Standard configuration
| Main body (including the transparent hood, control system, infant bed ) |
| Skin temperature sensor |
| Water trough |
| I.V.pole |
| Mattress |
| Cabinet with three drawers |
| Silence castors |
Qptional parts
| Infant bed pulled from side door |
| Infant bed pulled from front and side door |
| Double wall hood |
| Phototherapy up side unit |
Phototherapy from up and down sides |
| Tray/pole |
| RS232(485) connector |
ISO9001 ISO13485 CE